7.2.7.4   Special operation modes
A number of special energy saving modes are available to reduce maximum power consumption and/or average power consumption. For instance, power consumption can be limited by throttling the suction gas. Alternatively, a low fan speed can be used in chilled mode, a method which is advisable for non-respiring goods (e.g. nuts) or in CA mode.
 
To dehydrate the container, the refrigeration unit can be operated with the heating switched on, so that more water is condensed in the air cooler.
 